nav emailalert searchbtn searchbox tablepage yinyongbenwen piczone journalimg journalInfo journalinfonormal searchdiv searchzone qikanlogo popupnotification paper paperNew
2022, 03, v.25 14-17
发电厂直流保护系统研究
基金项目(Foundation): 河南省高等学校重点科研项目“发电厂直流系统故障主动监测与隔离技术研究及装置开发”(项目编号:21B470012)
邮箱(Email):
DOI:
发布时间: 2022-06-28
出版时间: 2022-06-28
移动端阅读
摘要:

分析了带隔直电容不平衡电桥法检测方法和直流系统故障隔离原理,提出发电厂直流系统故障隔离方案,设计了直流保护系统整体框架。该发电厂直流保护系统进行了试运行,结果表明该系统可准确预测直流系统故障并对故障进行隔离。

Abstract:

The detection method using unbalanced bridge with blocking capacitor and the principle of fault isolation for DC system are analyzed, the scheme of fault isolation for DC system of power plant is put forward, and an overall framework of DC protection system is designed. The trial operation of DC protection system of power plant is carried out,and the result indicates that the system is able to accurately predict the faults in DC system and isolate the faults.

基本信息:

中图分类号:TM721.1

引用信息:

[1]周永闯,周俊玲,周晓利,等.发电厂直流保护系统研究[J].山东电力高等专科学校学报,2022,25(03):14-17.

基金信息:

河南省高等学校重点科研项目“发电厂直流系统故障主动监测与隔离技术研究及装置开发”(项目编号:21B470012)