摘要:

介绍了变电站中阀控铅酸蓄电池的原理及其特点,分析了蓄电池的运行方式,指明使用维护及故障处理中应注意的事项,对用户提高对阀控铅酸蓄电池性能特点的了解,正确蓄电池使用和提高蓄电池的使用寿命具有一定的借鉴作用。

Abstract:

The paper introduced the principle and characteristics of substation valve control and sealed lead acid battery,analyzed the runmode of battery.It is pointed out the items of the notice in service and maintenance and disposal of malfunction,which has certain reference for users to understand the performances and characteristics of valve control and sealed lead acid battery,to use battery correctly,and to raise the service life ofbattery.

参考文献

[1]电力系统用蓄电池直流电源装置运行与维护技术规程[S]-DL/T 724-2000

[2]站用阀控铅酸(VRLA)蓄电池的维护、测试和更换方法[S]-IEEE站用蓄电池标准合作专业委员会

基本信息:

中图分类号:TM912.1

引用信息:

[1]刘伟洲.阀控铅酸蓄电池在变电站的运行与维护[J].山东电力高等专科学校学报,2007,No.31(01):79-81.